General information
•4 levels of water level checking, viz. 1/4th, half, 3/4thand full
•Receiver has 30Amps potential free contact relay
•Do not directly couple a motor to the receiver relay(always use external relay to trigger)
•Signal range 3 – 4 kms (line of sight)Conditions for pump ON/OFF
•When overhead tank water level is 1/4thor below => pumpON
•When overhead tank water level is FULL or more => pumpOFFFlow of waterFloat sensors
Model: FBXPC03A water level sensor + transmitter1 output signal lineLoop back to 4 input signal lines Each connected to float switches or equivalent Indicators Wireless automatic water level controller
•Power: GREEN
•Sync: BLUE
•1/4thwater level: RED
•Half water level: RED
•3/4thwater level: RED
•Full water level: REDTechnical details:
•Transmitter with external PA +28dbm
•Operating frequency: 380 – 480 MHz
•System operates works on signal hop mechanism. Sig
naltransmission happens at more than 12-15 predefined
frequencies
•Modulation type: GFSK
•Radio IC: CC1100 (Chipcon/TI) and other equivalents in sub-GHz freq.
•Modulation: GFSK
•Data packet error correction mechanism: FEC Connection wiring diagram:
Level sensor unit has a 6 point connector, of which2 are for power supply and the remaining 4 are for signal level checking.The main signals loops back through a level sensor/ float sensor(potential free contacts) to the respective level inputs. The red
line shown in the picture contains the pulsating current of veryfeeble strength.
Operating voltage:110-220VAC/50-60Hz to 12VDC converter adapter supplied.
Unit can also be plugged to any 12V external battery. Active working hours depends on the battery power.
Application and features:
- Turning motor pump ON/OFF from a distant location
- Automation / manual mode of operation
- Automatic mode: Remote controller used to turn ON/OFF
- Manual mode: Existing pump starter used to turn ON/OFF
- (In manual mode, remote controller signals are bypassed)
Model: FBXPC03A receiver with automatic ON/OFF switch2 output terminal through 30Amps potential free contact Manual switch to bypass the wireless signal from the
transmitter Indicators Wireless automatic water level controller
•Power: GREEN
•Sync: BLUE
•Mode: YELLOW: manual / radio
Tank level indicators
•1/4th water level: RED
•Half water level: RED
•3/4th water level: RED
•Full water level: RED Technical details:
•Operating frequency: 380 – 480 MHz
•Receiver operates works on signal hop mechanism. R
eception happens at more than 12-15 predefined frequencies
•Modulation type: GFSK
•Radio IC: CC1100 (Chipcon/TI) and other equivalents in sub-GHz freq.
•Receiver sensitivity: – 112 dbm
•Modulation: GFSK
•Data packet error correction mechanism: FEC
•1m wire / rubber duck antenna (+3dbi) Precautions and mounting locations:
•Avoid connecting relay contactor directly to motors (initial startup
surge currents will damage the device)
•Mounted on the top of wall
•Easy mounting with 4 screws to secure it tightly
•IP65 enclosure unit, robust and weatherproof
•Suitable for out door applications as well
•Keep away antennas from external metallic enclosures
Operating voltage:110-220VAC/50-60Hz to 12VDC converter adapter supplied.Unit can also be plugged to any 12V external battery. Active working hours depends on the battery power.
Application and features:
- Turning motor pump ON/OFF from a distant location
- Automation / manual mode of operation
- Automatic mode: Remote controller used to turn ON/OFF
- Manual mode: Existing pump starter used to turn ON/OFF
- (In manual mode, remote controller signals are bypassed)
Transmitter unit:
Enclosure type: IP 65 (color grey)
Size: 190 x 90 x 55 mm
Weight: 350gms
Metallic enclosure dimension:300 x 300 x 170 mm
Weight: 4500 gms
Receiver unit:
Enclosure type: IP 65 (color grey)
Size: 190 x 90 x 55 mm
Weight: 350gms
Metallic enclosure dimension:300 x 300 x 170 mm
Weight: 4500 gms